Effects of polycarboxylic acid water-reducing agent on construction performance and quality 1. Adaptability of cement, adaptability of admixture, treatment of bubble, whether to add defoaker.When the concrete arrives at the construction site, the unloading time should not be too long.The plastic loss of polycarboxylic acid admixtures after 2 hours is faster than that of neisser-system concrete, so it should be careful not to bond and masonry the tank.
Before each opening, the concrete truck should be flushed and drained in time.It is strictly prohibited to mix with other series of additives such as nai system, which is prone to abnormal accidents such as fast solid state.After using the POLYcarboxylic acid superplasticizer, the driver should hand over the remaining nai system additives to the meeting material department and refill the new polycarboxylic acid superplasticizer after cleaning the bucket.
Polycarboxylate superplasticizer is not suitable for storage in iron containers.Suitable for plastic, stainless steel, enamel and other materials.When using the original can, the inner wall should be cleaned before preservation.Can not be mixed with other admixtures, may cause rapid condensation and other abnormal phenomena.
The effect of intensity improvement is better.Adding polycarboxylate superplasticizer can greatly improve the early strength of concrete and shorten the construction period.