A few minutes later, the cement solidification speed suddenly became faster, and the so-called rapid setting phenomenon appeared. Through analysis, the cause of the abnormal phenomenon was finally determined: the gypsum, mixed materials, and mineral raw materials in the cement are not suitable for water reducing agents. In view of the above circumstances, when practitioners find that the fluidity of the concrete is deteriorated or the rapid setting phenomenon occurs after the concrete is mixed with a qualified water-reducing agent, the construction method of forcibly adding water should not be used, but should start from the adaptability of the cement and the water-reducing agent. The solution is to ensure the quality of the finished concrete product to the greatest extent. When using different kinds of admixtures, it is necessary to pay great attention to their compatibility to prevent the performance of concrete from being adversely affected. Falling and leading to poor cohesion, water retention, fluidity, etc.