Polycarboxylate superplasticizer is a kind of high-performance superplasticizer. It is a high-performance superplasticizer and a cement dispersant in the application of cement concrete.
So do you know what is the test method for the solid content of polycarboxylic acid water reducer?
Here is to introduce to you:
1. Install
Put the instrument on the test bench of the plane, then gently lift the heating cylinder, put the tripod on the sample plate and connect the power supply to start up, the instrument began to self-test.
2. The calibration
Calibrate the instrument, the method of calibration: press the calibration key, when the meter shows -20-, put the weight on the weighing plate.
The instrument shows the weight when the calibration is complete.
3. Sampling test
Take the sample evenly on the weighing plate, close the heating cylinder, and then press the test button, heating lamp on, the instrument for testing.
The temperature window displays the temperature during the moisture measurement process.
4.End.
The instrument automatically stops heating and gives an alarm sound. The moisture value is locked and displayed in the data window, and the moisture value is recorded.
If you want to view other data at this time, you can press the display key to view it successively. Note: if you are connected to the printer, you can directly press the print key to print out the moisture value.
The above is about the Polycarboxylate superplasticizer solid content detection method is related to the introduction, through the introduction of the above I believe you also understand in detail.
In addition, it should be noted that before the solid content test of polycarboxylic acid water reducer, the glue sample needs to be shaken well, and the glue head dropper is used to absorb the glue and put it into the sample plate. After the test, the sample plate should be removed when the temperature drops.